Fixed Film Technologies for Wastewater Treatment, Notes

Fixed film technologies are wastewater treatment methods where microorganisms grow on a stationary surface (a “film”) and treat wastewater as it flows over or through these surfaces. These technologies are widely used due to their simplicity, cost-effectiveness, and high efficiency in organic pollutant removal.


1. Trickling Filters (TFs):

Description:

  • Wastewater is distributed over a bed of porous media (rocks, plastic, or other materials) covered with a biofilm of microorganisms.
  • As wastewater trickles down through the media, the biofilm degrades organic pollutants.

Key Features:

  • Media: Rocks, plastic, or synthetic materials.
  • Aeration: Passive (air flows naturally through the filter).
  • Maintenance: Low.
  • Applications: Small to medium-sized wastewater treatment plants.

Advantages:

  • Simple design and operation.
  • Low energy requirements.
  • Resistant to shock loads.

Disadvantages:

  • May require a secondary clarifier to remove sloughed biofilm.
  • Limited flexibility in handling high-strength wastewater.

2. Rotating Biological Contactors (RBCs):

Description:

  • A series of circular discs mounted on a horizontal shaft partially submerged in wastewater.
  • The discs rotate slowly, alternately exposing the biofilm to wastewater and air.

Key Features:

  • Media: Discs made of plastic or other lightweight materials.
  • Aeration: Passive (provided during rotation).
  • Applications: Small-scale and decentralized wastewater treatment.

Advantages:

  • Compact and space-efficient.
  • Good oxygen transfer efficiency.
  • Reliable and low operational costs.

Disadvantages:

  • Sensitive to low temperatures.
  • Limited to low to medium organic loads.

3. Moving Bed Biofilm Reactor (MBBR):

Description:

  • Utilizes free-floating plastic carriers with high surface area for biofilm attachment.
  • Carriers are kept in suspension by aeration or mechanical mixing within the reactor.

Key Features:

  • Media: Plastic carriers with a large surface area.
  • Aeration: Mechanical or air diffusers.
  • Applications: Municipal and industrial wastewater treatment.

Advantages:

  • High treatment efficiency in a small footprint.
  • Resistant to shock loads and variable flow rates.
  • Easy to retrofit into existing treatment plants.

Disadvantages:

  • Requires energy for aeration or mixing.
  • Periodic maintenance of carriers may be needed.

4. Integrated Fixed Film Activated Sludge (IFAS):

Description:

  • Combines conventional activated sludge (suspended growth) with fixed biofilm on carriers or media.
  • Enhances biomass concentration and treatment efficiency.

Key Features:

  • Media: Fixed or free-floating media added to aeration tanks.
  • Aeration: Mechanical or air diffusers.
  • Applications: Upgrading existing activated sludge plants.

Advantages:

  • High capacity and flexibility.
  • Can handle higher organic loads.
  • Ideal for plant upgrades with space constraints.

Disadvantages:

  • Requires additional aeration.
  • High initial cost for media.

5. Submerged Aerated Filters (SAFs):

Description:

  • Wastewater flows through a submerged bed of media where biofilm forms.
  • Air is diffused through the bed to supply oxygen for aerobic processes.

Key Features:

  • Media: Inert materials like plastic, gravel, or ceramic.
  • Aeration: Air diffusers supply oxygen.
  • Applications: Small-scale treatment systems and package plants.

Advantages:

  • Compact design.
  • High oxygen transfer efficiency.
  • Low sludge production.

Disadvantages:

  • Requires energy for aeration.
  • Potential for clogging if not maintained.

6. Packed Bed Reactors (PBRs):

Description:

  • Similar to trickling filters but typically use engineered media packed into a reactor.
  • Wastewater flows either downward (gravity-driven) or upward (pumped).

Key Features:

  • Media: Plastic, ceramic, or other synthetic materials.
  • Aeration: Passive or active, depending on flow direction.
  • Applications: Industrial and high-strength wastewater treatment.

Advantages:

  • High efficiency in organic load removal.
  • Minimal maintenance.
  • Adaptable to various wastewater types.

Disadvantages:

  • Limited by hydraulic capacity.
  • May require pre-treatment for high solids content.
Packed Bed Reactors

Comparison of Fixed Film Technologies:

TechnologyOrganic Load CapacityFootprintEnergy RequirementMaintenanceApplications
Trickling Filters (TFs)Low to MediumMediumLowLowMunicipal wastewater
Rotating Biological Contactors (RBCs)Low to MediumCompactLowLowSmall-scale treatment
Moving Bed Biofilm Reactor (MBBR)Medium to HighCompactModerateModerateIndustrial wastewater
Integrated Fixed Film Activated Sludge (IFAS)HighMediumModerate to HighModeratePlant upgrades
Submerged Aerated Filters (SAFs)MediumCompactModerateModerateDecentralized systems
Packed Bed Reactors (PBRs)HighCompactLow to ModerateLowIndustrial treatment

Fixed film technologies offer robust solutions for wastewater treatment, catering to varying organic loads, space availability, and operational constraints. Selection depends on specific treatment goals, scale, and economic considerations.

Leave a comment